PURPOSE: field inhomogeneity artifacts arising from remote locations in the FOV and encountered in accelerated 3D gradient-recalled echo (GRE) sequences at ultra-high field, and at providing mitigation strategies. METHODS: Measurements were conducted at 11.7T using a head-shaped phantom and an accelerated 3D GRE…
#field inhomogeneity
Content tagged with "field inhomogeneity"
MRI-NUFFT is a python package that provides a universal interface to various Non-Uniform Fast Fourier Transform libraries running on CPU or GPU (gpuNUFFT, finufft, cufinufft, pyNFFT), adding compatibility with standard array library (NumPy, CuPy, PyTorch, TensorFlow, etc.) On top of these libraries it extends the…
Motivation: Non-Cartesian imaging remains complicated to use for MRI due to the high computational cost of the Non-Uniform Fourier Transform for image reconstruction. Goal(s): To provide a uniform interface for reconstructing magnetic resonance images from non-Cartesian k-space data and a collection of non-Cartesian…
Non-Cartesian sampling patterns allow for highly accelerated MRI exams at the cost of exacerbated and more complex artifacts, each impacting image quality in unique ways. Patient-induced B0 field inhomogeneities can notably cause distortions and blurring, but some trajectories are by design more robust to them.
The benefit of retrospective correction of static and dynamic B0 field imperfections was studied on non-Cartesian compressed sensing-based acquisition patterns by taking as an example 3D-SPARKLING encoding scheme. Long-TR dynamic acquisitions of T2*-weighted MRI (fMRI-like) volumes were acquired at 7T, retrospectively…
We augment the recently introduced SPARKLING algorithm and propose an improved mathematical formulation that takes the temporal dependence of the MR signal into account. This prevents the trajectories from sampling similar portions of k-space at different times, thereby reducing distortions and blurring induced by (B0…
Purpose Static and dynamic field imperfections are detrimental to functional MRI (fMRI) applications, especially at ultra‐high magnetic fields (UHF). In this work, a field camera is used to assess the benefits of retrospectively correcting field perturbations on Blood Oxygen Level Dependent (BOLD) sensitivity in…
Purpose Non‐Cartesian MRI with long arbitrary readout directions are susceptible to off‐resonance artifacts due to patient induced inhomogeneities. This results in degraded image quality with strong signal losses and blurring.
Conception et apprentissage de trajectoires d'échantillonnage non cartésiennes dans l'espace k pour l'IRM 3D accélérée L'imagerie par résonance magnétique (IRM) est une technique d'imagerie médicale non invasive très répandue qui permet de comprendre les structures des tissus du corps humain. Cependant, sa portée et…
Preprint (arXiv) · HAL (Le Centre pour la Communication Scientifique Directe) · 2022