MRI-NUFFT is an open-source Python library that provides state-of-the-art non-Cartesian MRI tools: trajectories, data loading, fast and memory-efficient operators to be used on laptops, clusters, and MRI consoles.
#non-cartesian sampling
Content tagged with "non-cartesian sampling"
Purpose: T1-weighted MPRAGE remains a cornerstone of clinical anatomical imaging, yet its long acquisition times constrain routine use. Established acceleration techniques, namely Parallel Imaging (PI) and Compressed Sensing (CS), tend to introduce substantial noise and blurring when pushed to high acceleration…
While highly accelerated non-Cartesian acquisition protocols significantly reduce scan time, they often entail long reconstruction delays. Deep learning based reconstruction methods can alleviate this, but often lack stability and robustness to distribution shifts.
Motivation: Deep Neural Networks (DNNs) show promise in reconstructing undersampled MRI data but face challenges with non-Cartesian 3D multi-coil acquisitions due to high memory demands and training complexity. Goal(s): To address the research gap in validating DNNs performances for non-Cartesian data in 3D multi-coil…
Motivation: Well established clinically used parallel imaging techniques like GRAPPA and CAIPIRINHA are mostly limited to Cartesian sampling, and their extension to non-Cartesian sampling is not direct. Goal(s): We propose to extend the SPARKLING framework to ensure GRAPPA accelerated Cartesian sampling in k-space…
MRI-NUFFT is a python package that provides a universal interface to various Non-Uniform Fast Fourier Transform libraries running on CPU or GPU (gpuNUFFT, finufft, cufinufft, pyNFFT), adding compatibility with standard array library (NumPy, CuPy, PyTorch, TensorFlow, etc.) On top of these libraries it extends the…
Motivation: Non-Cartesian imaging remains complicated to use for MRI due to the high computational cost of the Non-Uniform Fourier Transform for image reconstruction. Goal(s): To provide a uniform interface for reconstructing magnetic resonance images from non-Cartesian k-space data and a collection of non-Cartesian…
Non-Cartesian sampling patterns allow for highly accelerated MRI exams at the cost of exacerbated and more complex artifacts, each impacting image quality in unique ways. Patient-induced B0 field inhomogeneities can notably cause distortions and blurring, but some trajectories are by design more robust to them.
Cartesian sampling can acquire a given k-space region with minimum redundancy, while non-Cartesian sampling can help achieve a larger k-space coverage. Through generalized affine constraints in SPARKLING and an adapted target sampling density, for the first time non-Cartesian and Cartesian sampling are merged within…
The quest for higher spatial and/or temporal resolution in functional MRI (fMRI) while preserving a sufficient temporal signal-to-noise ratio (tSNR) has generated a tremendous amount of methodological contributions in the last decade ranging from Cartesian vs. non-Cartesian readouts, 2D vs.
The benefit of retrospective correction of static and dynamic B0 field imperfections was studied on non-Cartesian compressed sensing-based acquisition patterns by taking as an example 3D-SPARKLING encoding scheme. Long-TR dynamic acquisitions of T2*-weighted MRI (fMRI-like) volumes were acquired at 7T, retrospectively…
We augment the recently introduced SPARKLING algorithm and propose an improved mathematical formulation that takes the temporal dependence of the MR signal into account. This prevents the trajectories from sampling similar portions of k-space at different times, thereby reducing distortions and blurring induced by (B0…
For the first time, non-Cartesian 3D-SPARKLING (Spreading Projection Algorithm for Rapid K-space sampLING) encoding scheme was used for task-based fMRI (retinotopic mapping) at 7T. Additionally, this new acquisition technique was compared with 3D-EPI, considered as one of the reference acquisition schemes in…
Quantitative 23Na MRI provides useful information about brain tissue homeostasis. Most sequences use deterministic non-Cartesian 3D trajectories such as TPI.
Conception et apprentissage de trajectoires d'échantillonnage non cartésiennes dans l'espace k pour l'IRM 3D accélérée L'imagerie par résonance magnétique (IRM) est une technique d'imagerie médicale non invasive très répandue qui permet de comprendre les structures des tissus du corps humain. Cependant, sa portée et…
Compressed sensing in magnetic resonance imaging essentially involves the optimization of (1) the sampling pattern in k-space under MR hardware constraints and (2) image reconstruction from undersampled k-space data. Recently, deep learning methods have allowed the community to address both problems simultaneously,…
We benchmark the current existing methods to jointly learn non-Cartesian k-space trajectory and reconstruction: PILOT, BJORK, and compare them with those obtained from the recently developed generalized hybrid learning (HybLearn) framework. We present the advantages of using projected gradient descent to enforce MR…
Deep Learning has become a very promising avenue for magnetic resonance image (MRI) reconstruction. In this work, we explore the potential of unrolled networks for non-Cartesian acquisition settings.
Compressed sensing (CS) in Magnetic resonance Imaging (MRI) essentially involves the optimization of 1) the sampling pattern in k-space under MR hardware constraints and 2) image reconstruction from the undersampled k-space data. Recently, deep learning methods have allowed the community to address both problems…
The SPARKLING algorithm was originally developed for accelerated 2D magnetic resonance imaging (MRI) in the compressed sensing (CS) context. It yields non-Cartesian sampling trajectories that jointly fulfill a target sampling density while each individual trajectory complies with MR hardware constraints.
Over the last decade, the combination of compressed sensing (CS) with acquisition over multiple receiver coils in magnetic resonance imaging (MRI) has allowed the emergence of faster scans while maintaining a good signal-to-noise ratio (SNR). Self-calibrating techniques, such as ESPiRIT, have become the standard…